|
|
Rotor, bucket, tube rack, table for the
8410 model |
Rotor
Name |
Nominal
Capacity |
Tube
Size (mm)
diam. x length |
Maximum
Speed (rpm) |
Maximum
RCF (xg) |
Bucket
Code No. |
Tube
Rack
Adaptor Code No. |
Swinging
Bucket Rotor |
RS-3011 |
160
x 1.8mL Sample cup |
17
x 38(38)(*7) |
3,300 |
2,280 |
053-5310 |
055-4950 |
140
x 6mL/RIA tube |
10-12
x 65-100(95)(*7) |
3,300 |
2,150(*1) |
053-5310 |
055-5830 |
100
x 10mL |
12-14.5
x 75-110(105)(*7) |
3,300 |
2,280 |
053-5310 |
055-5840 |
80(64)
x 15mL |
14.5-17.2
x 75-110(105)(*7) |
3,300 |
2,280 |
053-5310 |
055-5850 |
16
x 15/50mL |
15mL
14.5-17.2 x 75-135(125)(*7) |
3,300 |
2,280 |
053-5310 |
055-5860 |
50mL
27-36 x 75-115(110)(*7) |
48
x 15mL Conical (TC) |
17
x 121(121)(*7) |
3,300 |
2,280 |
053-5310 |
055-4660 |
24
x 50mL Conical (TC) |
30
x 117(117)(*7) |
3,300 |
2,280 |
053-5310 |
055-4610 |
8
x 100mL |
38-46.5
x 75-120(116)(*7) |
3,300 |
2,280 |
053-5310 |
055-5870 |
4
x 250mL |
60-61.8
x 100-141(136)(*7) |
3,300 |
2,280 |
053-5310 |
055-6880 |
4
x 350mL |
65-71
x 100-130(122)(*7) |
3,300 |
2,280 |
053-5310 |
055-6890 |
96
x 10mL |
12-14
x 75-110 |
3,300 |
2,240(*1) |
053-5180 |
055-0200 |
72
x 15mL |
14.5-17.2
x 75-110 |
3,300 |
2,280 |
053-5180 |
055-0210 |
16
x 50mL |
27-36
x 75-114 |
3,300 |
2,280 |
053-5180 |
055-0240 |
48
x 15mL Conical (TC) |
17
x 121 |
3,300 |
2,280 |
053-5180 |
055-0220 |
16
x 50mL Conical (TC) |
30
x 117 |
3,300 |
2,280 |
053-5180 |
055-0230 |
4
x 250mL(*5) |
60-61.8
x 100-141 |
3,300 |
2,280 |
053-5180 |
055-4490 |
4
x 350mL |
65-71
x 100-130 |
3,300 |
2,280 |
053-5180 |
055-5880 |
4
x 500mL Conical (TC) |
96
x 147 |
3,300 |
2,280 |
053-5180 |
431124
(*8) |
4
x 650mL |
84-86
x 100-125 |
3,300 |
2,280 |
053-5180 |
055-5890 |
4
x 750mL |
95-97.5
x 100-135 |
3,300 |
2,280 |
053-5180 |
- |
8
x Microtiter Plate |
88(W)
x 134(D) x 50(H) |
3,300 |
2,020(*1) |
053-5220 |
- |
4
x Deep-well Plate |
3,300 |
2,020(*1) |
053-5220 |
- |
8
x Microtiter Plate |
92(W)
x 133(D) x 36(H) |
2,000 |
770(*1) |
053-5170 |
055-5900 |
8
x Tissue-culture Plate |
2,000 |
770(*1) |
053-5170 |
- |
RS-730
(*6) |
80
x RIA tube |
12
x 75-110 |
4,000 |
3,260 |
S13215 |
S18005 |
48
x 7mL blood collecting tube |
12.5-13
x 75-106 |
4,000 |
3,260 |
S13215 |
S18012 |
48
x 15mL(*3) |
15.5-17
x 96-115 |
4,000 |
3,260 |
S13215 |
S18015 |
16
x15mL Conical (TC) |
16.5
x 120.6 |
4,000 |
3,260 |
S13215 |
S18016 |
8
x 50mL Conical (TC)(*2) |
29.5
x 117 |
4,000 |
3,260 |
S13215 |
S18052 |
28
x 50mL Conical (TC) |
29.5
x 117 |
4,000 |
3,400(*1) |
S13235 |
- |
12
x Microtiter Plate(*4) |
86(W)
x 130(D) x 49(H) |
4,000 |
2,880(*1) |
S13220 |
- |
4
x Deep-well Plate(*4) |
4,000 |
2,880(*1) |
S13220 |
- |
Fixed
Angle Rotor |
RA-288M2 |
24
x 12mL |
15.9-16.5
x 97-120 |
6,000 |
4,830 |
- |
- |
RA-410M2 |
8
x 15mL Conical (TC) |
17
x 121 |
6,000 |
4,750 |
- |
055-1280 |
8
x 50mL Conical (TC) |
30
x 117 |
6,000 |
4,830 |
- |
- |
RA-500M2 |
10
x 50mL |
26.4-29.2
x 98-121 |
6,000 |
4,830 |
- |
- |
Microtiter
Plate Rotor |
PT-20
(*1) |
6
x Microtiter Plate(*4) |
86(W)
x 128(D) x 52(H) |
3,300 |
1,220 |
bucket
included |
- |
2
x Deep-well Plate(*4) |
PT-21
(*1) |
6
x Microtiter Plate(*4) |
86(W)
x 130(D) x 62(H) |
3,300 |
1,350 |
bucket
included |
- |
2
x Deep-well Plate(*4) |
PT-89
(*1) |
8
x Microtiter Plate(*4) |
86(W)
x 130(D) x 89(H) |
2,400 |
1,080 |
bucket
included |
055-6370 |
4
x Deep-well Plate(*4) |
|
|
(*1) |
More information for
the display of centrifugal force and the detection of
over speed, please refer the Instruction Manual. |
(*2) |
FALCON®, SARSTEDT®,
Lab-Tek®, GREINER(White), and IWAKI 50mL conical can
tube can use shield covers. |
(*3) |
When shield covers are
used, tubes cannot be inserted in the tube holes at the
four corners of the bucket. Accordingly, the number of
tubes for each bucket is reduced by four tubes. (Example:
When 15mL glass tubes are used in bucket S13215, up to
32 tubes can be used). |
(*4) |
If microtiter plates
are used, it is possible to stack them in double or more
on each bucket. However, be sure to test the strength
of those plates prior to centrifugation. The microtiter
plate at the bottom may be crushed. |
(*5) |
175mL Falcon conical
tube (code no. 2076) needs a cushion adapter (code no.
2090).
200mL Nalge Nunc conical tube (code no. 376813) needs
a cushion adapter (code no. 377585).
225mL Falcon conical tube (code no. 2075) needs a cushion
(code no. 2090) |
(*6) |
Intending to spin the
RS-730 swinging bucket rotor at 4,000 rpm, please contact
us. |
(*7) |
The length inside ()
includes the length of shield cover (code no. 027-9210). |
(*8) |
Cushion adapter made
by Corning. |
|
|