更多信息 6200型 |
|
Memory flashing (Patent pending) |
The memory flashing function makes the spin-down easy and simple by storing previous spinning time automatically then recalling repeatedly. Pressing the flashing key, same operation whose spinning time is from 1 second to 90 seconds can be repeated. |
|
Five channel memory settings |
The memory setting function makes routine work easy and simple, storing centrifugal speed, RCF and time. It is possible to save, recall and operate the centrifugal condition just by pushing the program switches. |
|
Rotor compatibility with micro centrifuge |
The 6200 has a rotor compatible with other micro refrigerated centrifuges (3700 series) and 3400. Thus, those who posses a 3700 series or 3400 can enjoy sharing rotor with 6200. |
|
Automatic rotor identification (Patent pending) and one-touch rotor function |
The automatic rotor identification and one-touch rotor functions, developed using KUBOTA's advanced technologies, facilitate easy interchange of rotors. These functions enable changing rotors, corresponding to applications’ requirements, without setting the rotor IDs or fastening rotors. |
|
Biohazard-proof Rotor |
Certified biohazard-proof rotors to ensure all aerosols and liquid from samples remain between the rotor and its lid (CAMR test certified).
|
|
Multi rotor for micro tubes, MF-2036 |
The MF-2036, a multi rotor for micro tubes, provides a reasonable solution to apply various types and sizes of tubes simply by changing buckets. For example, the MF-2036 accepts 8 PCR-strips, and 0.4, 0.5 and 2mL tubes. |
|
返回页首 |
g.sec integrator function |
The g.sec integrator function optimizes the protocols in those cases where customers need to achieve exactly the same centrifugal effect. One can obtain the same effect just by setting the g.sec value in the 6200 model. The g.sec integrator function enables one to control centrifuge spins with the same centrifugal effect and to calculate g.sec value. |
|
Acceleration/Deceleration (Three-level switching) |
The 6200 model provides Three-level switching for both acceleration and deceleration, corresponding to application requirements. For example, in those cases where one must avoid whirring up the samples, a slow deceleration can be programmed so as to achieve the desired conditions and most accurate results. |
|
Tachometer-port |
The 6200 has a tachometer-port on its lid to check the actual speed. The validation of the speed sensor by measuring the actual speed is highly needed for stringent GMP requirements. |
|
Alarm indicator and automatic stop functions |
Various alarm indicators and automatic stop functions improve safety further and stop the operation immediately after activation in the case of an emergency. The 6200 model is equipped with an alarm indication function including imbalance detection, abnormally high temperature detection, speed sensor and temperature sensor fault detection. The rotor sensor detects whether the rotor is set correctly to the drive shaft (patent pending). In addition, the unit is fitted with a circuit breaker. |
|
Foot pedal (Option) |
An optional foot pedal (option) allows hands-free lid opening, enabling the interlock mechanism to be released by a foot pedal. |
|
返回页首 |