更多信息 3780型 |
|
Three types of high speed micro refrigerated
centrifuges |
KUBOTA is producing three
types of high speed micro refrigerated centrifuges to
meet the various requirements of the customers. To see
the difference among them click below for more information.
|
|
Biohazard-proof rotor |
Biohazard-proof rotors
are ensured to maintain the aerosol and sample liquid
between the rotor and its lid, certified with CAMR standard
test procedures
|
|
Automatic rotor identification (Patent Pending)
and one-touch rotor function |
The automatic rotor identification
and one-touch rotor functions, developed using KUBOTA's
advanced technologies, facilitate easy interchange of
rotors. These functions enable changing rotors, corresponding
to applications requirements, without setting rotor IDs
or fastening rotors. |
|
Pre-cooling |
Pre-cooling function
saves the time to reach low temperature and the samples
that are easily deactivated in a normal temperature. Applying
samples with high speed takes long time to reach desired
low temperature. In such a case, pre-cooling enables getting
low temperature before the experiments and save the time.
In addition, Genomics experiments, such as DNA or RNA
purification, require keeping low temperature in order
to obtain valid test results. |
|
Multi rotor for micro tubes, MF-2036 |
The MF-2036, multi rotor
for micro tubes, provides reasonable solution to apply
various types and sizes of tubes only by changing buckets.
For example, the MF-2036 accepts 8 PCR-strips, 0.4, 0.5,
2mL tubes. |
|
g.sec integrator function |
G.sec integrator function
optimizes the protocols in the case customers need to
achieve exactly the same centrifugal effect. One can obtain
the same effect just by putting g.sec value in the 3780.
G.sec integrator function enables controlling centrifuges
with the same centrifugal effect and calculating g.sec
value. |
|
Acceleration/Deceleration (Three-level switching) |
The 3780 model provides
Three-level switching for both acceleration and deceleration,
corresponding to application requirements. Several samples
have to avoid whirring up. In such a case, slow deceleration
allows gaining the desired results properly. |
|
Foot pedal
(Option) |
Foot pedal (option) allows
hand-free lid opening. The interlock mechanism can be
released by a foot pedal. |
|
Alarm indicator and automatic stop functions |
Various alarm indicators
and automatic stop functions improve safety further and
stop the operation immediately after the case of emergency.
The 3780 model is equipped with the alarm indication function
such as imbalance detection, abnormally high temperature
detection, speed sensor and temperature sensor fault detection.
The rotor sensor detects whether the rotor is set correctly
to the drive shaft (Patent pending). In addition, circuit
breaker is fitted. |
|
返回页首 |