|
|
Swing rotor 7780型 |
|
Rotor
Name |
Nominal
Capacity |
Tube
Size (mm)
diam. x length |
Maximum
Speed
(rpm) |
Maximum
RCF
(xg) |
Bucket
Code No. |
Tube
Rack Adaptor
Code No. |
Swinging
Bucket Rotor |
RS-410G
(*1,2) |
48
x 2mL |
10.7
x 42 |
5,000 |
4,160 |
Bucket
included |
S17008 |
48
x 5mL RIA tube |
12.5
x 55-75 |
5,000 |
4,160 |
Bucket
included |
S17006 |
48
x 7mL |
12-12.5
x 100-112 |
5,000 |
4,160 |
Bucket
included |
S17007 |
28
x 7mL blood collecting tube |
12.5-13
x 75-106 |
5,000 |
4,160 |
Bucket
included |
S17027 |
12
x 15mL Conical (TC)(*3) |
16.5
x 120.6 |
5,000 |
4,160 |
Bucket
included |
S17019 |
12
x 15mL Conical (TC)(*3) |
16.5
x 120.6 |
5,000 |
4,470
(*7) |
S13130 |
- |
28
x 10mL blood collecting tube/15mL |
15.5-17
x 87-110 |
5,000 |
4,160 |
Bucket
included |
S17015 |
4
x 50mL |
27-35.8
x 82-110 |
5,000 |
4,160 |
Bucket
included |
055-5670 |
4
x 50mL Conical (TC) |
29.5
x 117 |
5,000 |
4,160 |
Bucket
included |
S17049 |
4
x 100mL |
44-45
x 110 |
5,000 |
4,160 |
Bucket
included |
S17100 |
4
x 200mL |
56.5
x 104 |
5,000 |
4,160 |
Bucket
included |
- |
返回页首 |
RS-720G |
80
x 2mL |
9.5-11
x 36-42 |
3,500 |
2,290
(*7) |
053-5820 |
055-4800 |
96
x 6mL RIA tube |
10-12.3
x 65-95 |
3,500 |
2,190
(*7) |
053-5820 |
055-4730 |
48
x 5/7m narrow blood collecting tube(*4) |
12-13.3
x 63-110 |
3,500 |
2,310 |
053-5820 |
055-4990 |
24
x 8mL CPT cell preparation tube(*5) |
13.5-15.8
x 81-130 |
3,500 |
2,310 |
053-5820 |
055-6900 |
80
x 10mL |
12.5-13.8
x 65-95 |
3,500 |
2,260
(*7) |
053-5820 |
055-4740 |
48
x 10m blood collecting tube/15mL |
15-17.2
x 81-110 |
3,500 |
2,330 |
053-5820 |
055-4750 |
68
x 5/7m narrow blood collecting tube(*4) |
12.5-13.7
x 62-110 |
3,500 |
2,300 |
053-5840 |
055-0260 |
68
x 10mL blood collecting tube/15mL |
15-17.2
x 52-110 |
3,500 |
2,300 |
053-5840 |
- |
28
x 15mL Conical (TC) |
17
x 121 |
3,500 |
2,300 |
053-5840 |
- |
32
x 15mL Conical (TC) |
17
x 121 |
3,500 |
2,330 |
053-5820 |
055-4780 |
8
x 50mL |
27-36.4
x 85-110 |
3,500 |
2,330 |
053-5820 |
055-4760 |
16
x 50mL Conical (TC) |
30
x 117 |
3,500 |
2,330 |
053-5820 |
055-6070 |
4
x 100mL |
38-46.5
x 75-120 |
3,500 |
2,330 |
053-5820 |
055-4770 |
4
x 175mL Conical (TC)(*6) |
61
x 118 |
3,500 |
2,330 |
053-5820 |
055-4850 |
4
x 200mL Conical (TC)(*6) |
61
x 130 |
3,500 |
2,330 |
053-5820 |
055-4850 |
4
x 225mL Conical (TC)(*6) |
61
x 137 |
3,500 |
2,330 |
053-5820 |
055-4850 |
4
x 250mL |
60-61.8
x 100-130 |
3,500 |
2,380
(*7) |
053-5820 |
055-4850 |
sputum tube
(self-standing type)(*8) |
- |
3,500 |
- |
053-5820 |
- |
|
|
|
(*1) |
Please confirm the delivery
schedule with your dealer. |
(*2) |
RS-410G Rotor can accommodate
sealing caps (code no. S17111) (Optional). |
(*3) |
The sealing cap cannot
be used with the combination of the original bucket and
S17019 tube rack.
The bucket for 12 x 15 conical (TC) tube (code no. 13130)
able to accept the sealing caps. |
(*4) |
5/7 mL narrow tube made
by Sekisui(Insepack II), Termo(Venoject II), Nipro(Neotube)
and Becton Dickinson(Vacutenar) can be used. Tube for
low cytoms can be used. |
(*5) |
The CTP cell preparation
tube is made by Becton & Dickinson (Vacutenar 8mL
for CPT single). |
(*6) |
The 175mL Conical (TC)
is made by Falcon Corporation (Code No. 352076) and requires
a cushion (Code No. 352090).
The 200mL Conical (TC) is made by Nalge Nunc International
(Code No. 376813) and requires a cushion adapter (Code
No. 377585).
The 225mL Conical (TC) is made by Falcon Corporation (Code
No. 352075) and requires a cushion (Code No. 352090). |
(*7) |
Regarding to the exact
centrifugal force indication, please consult an instruction
manual. |
(*8) |
Several types of sputum
tube will be acceptable with ST-720M and 053-5820 bucket.
For more information, please contact your local dealer. |
|
返回页首 |
|